Krykard Servo Stabilizer ( 3 - 3000 ) kVA

KRYKARD is the MOST TRUSTED Power Conditioning brand in India, by Industry, Corporates and OEMs, to protect their sensitive and critical equipment. KRYKARD Servo Stabilizers have set the standard in the industry for product design, quality and service in over 4,00.000 installations over the decades.

Yes I'm Interested
PARAMETER 3 PHASE UNBALANCED AIR COOLED 3 PHASE UNBALANCED OIL COOLED
Rating (kVA) 3 - 300 3 - 3000
Type of Cooling Air Oil
Input Voltage Range (V L-L) 310 - 480 / 340 - 480 / 360 - 480 310 - 480 / 340 - 480 / 360 - 480
Output Voltage (V L-L) 415 (380V/400V - optional) 415 (380V/400V - optional)
Output Voltage Regulation 1% of nominal output voltage 1% of nominal output voltage
Input Frequency Range 47Hz - 53Hz 47Hz - 53Hz
Efficiency >97% >97%
Effect of Load Power Factor Nil Nil
Waveform Distortion Nil Nil
Type of Servo Control Micro Controller based True RMS sensing and correction Micro Controller based True RMS sensing and correction
Servo Motor Drive Triac based drive for AC Step Synchronous motor Triac based drive for AC Step Synchronous motor
Under/ Over Voltage Cutoff Electronic cutoff circuit with graded time delay, set @ +5% / -10% of nominal output voltage Electronic cutoff circuit with graded time delay, set @ +5% / -10% of nominal output voltage
Overload Cutoff CT based Electronic cutoff circuit with graded time delay set @ 110% of rated full load current CT based Electronic cutoff circuit with graded time delay set @ 110% of rated full load current
Short Circuit Protection MCB / MCCB provided up to 100 kVA. Above 100 kVA MCCB optional MCB / MCCB provided up to 100 kVA. Above 100 kVA MCCB optional
Single Phasing Prevention Provided Provided
Phase Reversal Trip Provided Provided
Stabiliser Bypass Provided up to 50 KVA 3-phase; Optional > 50 kVA Provided up to 50 KVA 3-phase; Optional > 50 kVA
Transient Suppression Spike Suppression through MOV is provided (Surge Arrestor is optional) Spike Suppression through MOV is provided (Surge Arrestor is optional)
Emergency Off Switch Provided Provided
Frequency Cutoff Protection Optional Optional
Input High Voltage Trip Provided Provided
Event Log Optional - Up to 100 events with Date & Time stamp Optional - Up to 100 events with Date & Time stamp
Resetting Mode Manual / Auto option provided with programmable time delay Manual / Auto option provided with programmable time delay
Display Type 2 Line LCD Panel 2 Line LCD Panel
Parameters Displayed Input & Output Voltages (Line & Phase), Output Currents & Frequency, Fault Annunciation Input & Output Voltages (Line & Phase), Output Currents & Frequency, Fault Annunciation
LED Indications Input Status - 3-Colour LED - Green: Normal, Yellow: Out of Range, Red: Unsafe (Trip)
Output Status - 2-Colour LED - Green: Output On, Red: Output Trip
Input Status - 3-Colour LED - Green: Normal, Yellow: Out of Range, Red: Unsafe (Trip)
Output Status - 2-Colour LED - Green: Output On, Red: Output Trip
Input / Output Terminations Bolted Terminals up to 100kVA, Busbar 125kVA and above Bolted Terminals up to 100kVA, Busbar 125kVA and above