93PR FEATURES AND BENEFITS
Smaller footprint
Modular and Hot-Swappable
Silicon carbide IGBT based power converter
Microprocessor based advanced algorithm
Lithium-ion battery compatible
Eaton EnergyAware technology
Ideal for mission-critical applications in:
Data centres
Healthcare
Commercial buildings
Control centres
Process Industries
Extra Low Total Cost of Ownership
Compact footprint and internal redundancy design
Vertical scalability reduces cost and future growth risks
High efficiency (> 97%) in double conversion model
Hot Sync Technology
Eliminates single point of failure in parallel systems
Enhances system reliability
Cable Entry & Connectivity
Top and bottom cable entry
Built-in device and host USB
Alarm inputs and relay outputs
Supports multiple communication protocols (HTTP(S), SNMP, MODBUS, BACnet IP)
7” Color touchscreen display with LED indicators
Lithium-ion Battery System
Advanced Battery Management System (BMS)
Superior energy density, long cycle life, and lower TCO
Seamless integration with Eaton Power Xpert UPS models
Wide range of runtime options (3 min to 1+ hour)
Yes I'm Interested
| Model | 93PR-300 | 93PR-400 (600 kW) | 93PR-600 | 93PR-800 |
|---|---|---|---|---|
| Power rating (kW) | 300 kW N+1 | 400 kW N+1 (600 kW frame capacity) | 600 kW N+1 | 800 kW N+1 |
| Power clustering (kW) | 300 kW (5 x 60 kW) common battery | 400 kW (6 x 60 kW) common battery | 600 kW (10 x 60 kW) common battery | 800 kW (10 x 80 kW) common battery |
| Feature | 93PR-300 | 93PR-400 (600 kW) | 93PR-600 | 93PR-800 |
|---|---|---|---|---|
| Frame offering | Standard input, output, MBS, bottom/top feed available, standard dust filters | Standard input, output, MBS, bottom/top feed available, standard dust filters | Standard input, output, MBS, bottom/top feed available, standard dust filters | Standard I/O panel & cables bottom/top feed available, standard dust filters |
| Parameter | Value |
|---|---|
| Efficiency in Energy Saver System (ESS) | Up to 99% |
| Efficiency in double conversion mode | Up to 97% |
| Parallel capability | 4 x parallel, extendable to 8 parallel, maximum 4.8 MW |
| Cold start | Available |
| Sub-distribution | Redundant wrap-up, compatible with generator setup in site configurable |
| Parameter | Value |
|---|---|
| Voltage | 380/400/415V |
| Voltage range | 304-478V L-L / 176-276V L-N |
| Frequency range | 40 - 70 Hz |
| Power factor detection | 1 |
| Harmonic distortion | <1% linear load, <3% nonlinear load |
| Voltage THD | <1% for linear load |
| Frequency THD | <3% for nonlinear load |
| Parameter | Value |
|---|---|
| Battery type | Lithium, VRLA, Ni-Cd |
| Battery connection options | Supports 10x common battery |
| Parameter | Value |
|---|---|
| Optional accessories | Communication Dry Contacts, ModBus RTU/TCP, SNMP cards, External Sync Control Bus, Top exhaust kits |
| Parameter | Value |
|---|---|
| EMC standard | IEC62040-2 |
| Safety standard | IEC62040-1 |
| Protection rating | IP20 |
| Dimensions (W x D x H) | 700 x 850 x 1900 mm, 2100 x 850 x 1900 mm, 2800 x 1300 x 1900 mm |
| Weight (kg) | 376, 500, 786 |
| Operating Temperature/Humidity | 0 - 40°C, workload derating / 5-95% RH, non-condensing |